Bypass diode failure
A failed module diode dragging down a whole string’s output.
A bypass diode failure is when one of the diodes that route current around a shaded or faulty cell-group fails short or open. A shorted diode disables a third of a module’s output; an open diode removes the protection and risks hot-spots. Either way the loss propagates to the whole series string and is easily mistaken for generic underperformance.
Symptoms
- A step drop in one string’s output that does not recover with cleaning.
- A module section running hot on a thermal scan (hot-spot or active diode).
- Output loss roughly in thirds — one, two, or three sub-strings of a module affected.
SCADA signatures
- Affected string current sits below siblings by a discrete step, not a gradual drift.
- The deficit is largely flat with irradiance rather than scaling smoothly.
- No matching irradiance/temperature anomaly — distinguishing it from soiling or shading.
Root cause
Bypass diodes fail from thermal cycling, lightning-induced surges, or sustained activation under partial shading, often ending shorted (a permanent third-of-module loss) or open (loss of hot-spot protection). Because each module typically has three diodes, the signature is loss in multiples of a third.
Financial impact
A handful of shorted diodes across a plant is a quiet few-percent yield loss; left unaddressed, an open diode allowing repeated hot-spotting can escalate into module damage or a fire-risk event, turning a cheap diode swap into a module replacement.
How NuraVolt detects it
NuraVolt benchmarks each string against its cohort and looks for the discrete, irradiance-flat step that distinguishes a diode failure from soiling or progressive resistance, then flags candidate strings for a targeted thermal inspection rather than a blind sweep.
Frequently asked questions
See also
A string delivering less current than its peers under the same irradiance.
Unequal power across the MPPT inputs of a single inverter.
Falling insulation resistance on the DC side — a safety-critical fault.
The plant metric a failed diode quietly drags down.
See this on your own plants
NuraVolt turns your SCADA and BMS data into early fault detection, degradation-aware BESS analytics, and audit-ready reporting. A fixed-scope audit shows you what we’d find on your portfolio.